Items |
0.02 class |
0.05 class |
0.1 class |
|
Accuracy of reference standard meter |
HS-5300H /0.02 |
HS-5300/0.05 |
HS-5300/ 0.1 |
|
Output range |
voltage:3×30~300V current:3×0.3m~120A |
voltage:3×30~300V current:3×0.3mA~120A(200A optional) |
||
Phase angle |
0~360°,resolution:0.01° |
|||
Frequency |
45~65Hz ,resolution:0.01Hz |
|||
Waveform distortion |
voltage、current<0.5%( liner load) |
|||
power stability |
≤0.02%/120s |
≤0.05%/120s |
||
Output capacity/each phase |
voltage:300VA(6positions) current:250VA(100A) |
Voltage:300VA(16positions) current:900VA(100A) Max load can rise to 2000VA for current with the increase of the position number, voltage 1200VA |
||
Load characteristic |
resistive, inductive and capacitive(less than 1uF/ each position, the Max. is less than 48 uF) |
|||
Starting current output |
Min.0.3mA, accuracy:2%, starting power: accuracy 5% |
|||
Communication test |
RS485/232/infrared/carrier wave, support DL/T645-1997/2007、698.45、IEC1107 |
|||
Environment condition |
Temp.:20℃±5℃;Humidity:<85% R.H. |
|||
Power supply |
AC220±10%,50/60Hz,AC120/240V(optional); |
Function Parameters:
Items |
HS-6303 |
HS-6303B |
HS-6303C |
HS-6303E |
HS-6303F |
HS-6303G |
HS-6303H |
|
Basic functions |
basic error |
● |
● |
● |
● |
● |
● |
● |
creeping test |
● |
● |
● |
● |
● |
● |
● |
|
starting test |
● |
● |
● |
● |
● |
● |
● |
|
standard deviation |
● |
● |
● |
● |
● |
● |
● |
|
Constant test |
● |
● |
● |
● |
● |
● |
● |
|
dial error |
● |
● |
● |
● |
● |
● |
● |
|
influence test |
● |
● |
● |
● |
● |
● |
● |
|
Multi-functions test
|
daily timing error☆ |
|
● |
|
〇 |
● |
|
〇 |
period switching error |
|
● |
|
〇 |
● |
|
〇 |
|
demand period error |
|
● |
|
〇 |
● |
|
〇 |
|
demand display error |
|
● |
|
〇 |
● |
|
〇 |
|
energy display error |
|
● |
|
〇 |
● |
|
〇 |
|
register checking |
|
● |
|
〇 |
● |
|
〇 |
|
GPS timing☆ |
|
〇 |
|
〇 |
〇 |
|
〇 |
|
communication test☆ |
|
● |
|
〇 |
● |
|
〇 |
|
state grid test |
consistency test |
|
〇 |
|
〇 |
● |
|
〇 |
Com. protocol consistency checking |
|
〇 |
|
〇 |
● |
|
〇 |
|
event record |
|
〇 |
|
〇 |
● |
|
〇 |
|
charge test☆ |
|
〇 |
|
〇 |
〇 |
|
〇 |
|
power consumption test☆ |
|
〇 |
|
〇 |
〇 |
|
〇 |
☆ is special function
Dimensions(unit: mm, position recommendation)
Integration |
Fission |
||||
position |
rack |
size: L×W×H(mm) |
position |
rack |
size: L×W×H(mm) |
6 |
1 |
2000×800×1600 |
12 |
1 |
2000×700×1920 |
Horizontal test bench can be provided |
16 |
1 |
2200×700×1920 |
||
12 |
1 |
2000×800×1920 |
24 |
2 |
2000×700×1920 |
16 |
1 |
2200×800×1920 |
32 |
2 |
2200×700×1920 |
24 |
2 |
2000×750×1920 |
cabinet |