Items |
0.03 class |
0.05 class |
0.1 class |
Accuracy of reference standard meter |
HS-5100H/0.02 |
HS-5100/0.05 |
HS-5100/0.1 |
Output range |
voltage:30 ~ 300V current:1mA ~ 120A |
voltage:30 ~ 300V current:1mA ~ 120A(200A optional) |
|
Phase angle |
0~360 °,resolution:0.01° |
||
Frequency |
45 ~ 65Hz ,resolution:0.01Hz |
||
Waveform distortion |
voltage、current< 0.5%(liner load) |
||
Power stability |
< 0.02%/120 s |
< 0.05%/120 s |
|
Output range |
voltage:200VA(6positions) current:250VA(100A) |
voltage:400VA(24 positions)current: 900VA(100A) Max load can rise to 2000VA for current with the increase of the position number, voltage 1200VA |
|
Load characteristic |
resistive, inductive, capacitive(less than 1uF/ each position, the Max. is less than 48 uF) |
||
Starting current output |
Min. 1mA, accuracy: ≤ 2%,starting power: accuracy≤ 2% |
||
Communication test |
RS485/232/ infrared / carrier wave, support DL/T645-1997/2007、698.45、IEC1107 |
||
Environment condition |
Temp.:20℃ ±5℃;Humidity:< 85% R.H. |
||
Power supply |
AC 220±10%,50/60Hz,AC120/240V(optional); Max. consumption:1500VA(24 positions) |
Dimensions(unit:mm, position recommendation)
Integration |
Fission |
||||
position |
rack |
size: L×W×H(mm) |
position |
rack |
size: L×W×H(mm) |
6 |
1 |
1600×750×1600 |
12 |
1 |
1600×700×1920 |
1600×800×1100(horizontal) |
24 |
1 |
2200×700×1920 |
||
12 |
1 |
1600×750×1920 |
48 |
2 |
2200×700×1920 |
24 |
1 |
2200×750×1920 |
60 |
2 |
2000×700×1920 |
48 |
2 |
2200×750×1920 |
cabinet |
600×800×1920(mm) |
Function Parameters:
Items |
HS-6103 |
HS-6103B |
HS-6103C |
HS-6103E |
HS-6103F |
HS-6103G |
HS-6103H |
|
Basic functions |
basic error |
● |
● |
● |
● |
● |
● |
● |
creeping test |
● |
● |
● |
● |
● |
● |
● |
|
starting test |
● |
● |
● |
● |
● |
● |
● |
|
standard deviation |
● |
● |
● |
● |
● |
● |
● |
|
Constant test |
● |
● |
● |
● |
● |
● |
● |
|
dial test |
● |
● |
● |
● |
● |
● |
● |
|
influence test |
● |
● |
● |
● |
● |
● |
● |
|
Multi-functions test
|
daily timing error☆ |
|
● |
|
〇 |
● |
〇 |
〇 |
period switching |
|
● |
|
〇 |
● |
〇 |
〇 |
|
energy display error |
|
● |
|
〇 |
● |
〇 |
〇 |
|
Register checking |
|
● |
|
〇 |
● |
〇 |
〇 |
|
GPS timing☆ |
|
〇 |
|
〇 |
〇 |
〇 |
〇 |
|
communication test☆ |
|
● |
|
〇 |
● |
〇 |
〇 |
|
State grid test |
consistency test |
|
〇 |
|
〇 |
● |
|
〇 |
Com. protocol consistency checking |
|
〇 |
|
〇 |
● |
|
〇 |
|
event record |
|
〇 |
|
〇 |
● |
|
〇 |
|
charge test☆ |
|
〇 |
|
〇 |
〇 |
|
〇 |
|
power consumption test☆ |
|
〇 |
|
〇 |
〇 |
|
〇 |